Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Evaluation of facial artery course variations, diameters, and depth by Doppler ultrasonography
Wei-Wei Shen1, Chen-Bo Jiao2, Jian-Xun Ma2
1Department of Ultrasound, Peking University Third Hospital, Beijing 100191, China.
Background:
The facial artery (FA) is the main blood vessel supplying blood to the face. It is essential to understand the anatomy of FA around the nasolabial fold (NLF). This study aimed to provide the detailed anatomy and relative positioning of FA to help avoid unexpected complications in plastic surgery.
Methods:
FA was observed from the inferior border of the mandible to the end of its terminal branch in 66 hemifaces of 33 patients with Doppler ultrasonography. The evaluation parameters were: (1) location, (2) diameter, (3) FA-skin depth, (4) relationship between the NLF and FA, (5) distance between the FA and significant surgical landmarks, and (6) the running layer. The FA course is classified based on the terminal branch.
Results:
The most common FA course was Type 1, which had an angular branch as the final branch (59.1%). The most common FA-NLF relationship was that the FA was situated inferior to the NLF (50.0%). The mean FA diameter was 1.56 ± 0.36 mm at the mandibular origin, 1.40 ± 0.37 mm at the cheilion, and 1.32 ± 0.34 mm at the nasal ala. The FA diameter on the right hemiface was thicker than that on the left hemiface (p < 0.05).
Conclusion:
The FA mainly terminates in the angular branch, running in the medial NLF and in dermis and subcutaneous tissue, with a blood supply advantage in the right hemisphere. We suppose that a deep injection into periosteum around the NLF may be safer than an injection into the superficial musculoaponeurotic system (SMAS) layer.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies II: Ultrasonography
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Ultrasonography
During an ultrasonography procedure, a handheld device called...