Related Experiment Video
Updated: Jul 1, 2026

Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
Automatic identification of intracranial pressure waveform during external ventricular drainage clamping:
Murad Megjhani1,2, Kalijah Terilli1,2, Soon Bin Kwon1,2
1Department of Neurology, Columbia University, NY, United States of America.
Abstract:
Objective. The objective of this study is to develop and validate a method for automatically identifying segments of intracranial pressure (ICP) waveform data from external ventricular drainage (EVD) recordings during intermittent drainage and closure.Methods. The proposed method uses time-frequency analysis through wavelets to distinguish periods of ICP waveform in EVD data. By comparing the frequency compositions of the ICP signals (when the EVD system is clamped) and the artifacts (when the system is open), the algorithm can detect short, uninterrupted segments of ICP waveform from the longer periods of non-measurement data. The method involves applying a wavelet transform, calculating the absolute power in a specific range, using Otsu thresholding to automatically identify a threshold, and performing a morphological operation to remove small segments. Two investigators manually graded the same randomly selected one-hour segments of the resulting processed data. Performance metrics were calculated as a percentage.Results. The study analyzed data from 229 patients who had EVD placed following subarachnoid hemorrhage between June 2006 and December 2012. Of these, 155 (67.7%) were female and 62 (27%) developed delayed cerebral ischemia. A total of 45 150 h of data were segmented. 2044 one-hour segments were randomly selected and evaluated by two investigators (MM and DN). Of those, the evaluators agreed on the classification of 1556 one-hour segments. The algorithm was able to correctly identify 86% (1338 h) of ICP waveform data. 8.2% (128 h) of the time the algorithm either partially or fully failed to segment the ICP waveform. 5.4% (84 h) of data, artifacts were mistakenly identified as ICP waveforms (false positives).Conclusion. The proposed algorithm automates the identification of valid ICP waveform segments of waveform in EVD data and thus enables the inclusion in real-time data analysis for decision support. It also standardizes and makes research data management more efficient.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
09:16Use of a Wireless Video-EEG System to Monitor Epileptiform Discharges Following Lateral Fluid-Percussion Induced Traumatic Brain Injury
Published on: June 21, 2019
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Curved Plate of Constant Width
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...