Related Experiment Video
Updated: Jul 26, 2025

Development and Implementation of a Multi-Disciplinary Technology Enhanced Care Pathway for Youth and Adults with Concussion
Published on: January 20, 2019
Development and Reliability of a Visual-Cognitive Reactive Triple Hop Test
Byrnadeen T Farraye1,2, Janet E Simon2,3, Meredith Chaput1,2
1Division of Physical Therapy, School of Rehabilitation and Communication Sciences, College of Health Sciences and Professions, Ohio University, Athens, OH,USA.
Context:
Current lower-extremity return to sport testing primarily considers the physical status of an athlete; however, sport participation requires continuous cognitive dual-task engagement. Therefore, the purpose was to develop and evaluate the reliability of a visual-cognitive reactive (VCR) triple hop test that simulates the typical sport demand of combined online visual-cognitive processing and neuromuscular control to improve return to sport testing after lower-extremity injury.
Design:
Test-retest reliability.
Methods:
Twenty-one healthy college students (11 females, 23.5 [3.7] y, 1.73 [0.12] m, 73.0 [16.8] kg, Tegner Activity Scale 5.5 [1.1] points) participated. Participants performed a single-leg triple hop with and without a VCR dual task. The VCR task incorporated the FitLight system to challenge peripheral response inhibition and central working memory. Maximum hop distance, reaction time, cognitive errors, and physical errors were measured. Two identical testing visits were separated by 12 to 17 days (14 [1] d).
Results:
Traditional triple hop (intraclass correlation coefficients: ICC(3,1) = .96 [.91-.99]; standard error of the measurement = 16.99 cm) and the VCR triple hop (intraclass correlation coefficients(3,1) = .92 [.82-.97]; standard error of the measurement = 24.10 cm) both demonstrated excellent reliability for the maximum hop distance, and moderate reliability for the VCR triple hop reaction time (intraclass correlation coefficients(3,1) = .62 [.09-.84]; standard error of the measurement = 0.09 s). On average, the VCR triple hop resulted in a hop distance deficit of 8.17% (36.4 [5.1] cm; P < .05, d = 0.55) relative to the traditional triple hop.
Conclusions:
Hop distance on the VCR triple hop had excellent test-retest reliability and induced a significant physical performance deficit when compared with the traditional triple hop assessment. The VCR triple hop reaction time also demonstrated moderate reliability.
More Related Videos
07:12Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025
13:09Using Brain Activation nir-HEG/Q-EEG and Execution Measures CPTs in a ADHD Assessment Protocol
Published on: April 1, 2018