Convolutional neural network framework for the automated analysis of transition metal X-ray photoelectron spectra
Lukas Pielsticker1, Rachel L Nicholls1, Serena DeBeer1
1Max Planck Institute for Chemical Energy Conversion, Stiftstr. 34-36, 45470, Muelheim an der Ruhr, Germany.
Abstract:
X-ray photoelectron spectroscopy is an indispensable technique for the quantitative determination of sample composition and electronic structure in diverse research fields. Quantitative analysis of the phases present in XP spectra is usually conducted manually by means of empirical peak fitting performed by trained spectroscopists. However, with recent advancements in the usability and reliability of XPS instruments, ever more (inexperienced) users are creating increasingly large data sets that are harder to analyze by hand. In order to aid users with the analysis of large XPS data sets, more automated, easy-to-use analysis techniques are needed. Here, we propose a supervised machine learning framework based on artificial convolutional neural networks. By training such networks on large numbers of artificially created XP spectra with known quantifications (i.e., for each spectrum, the concentration of each chemical species is known), we created universally applicable models for auto-quantification of transition-metal XPS data that are able to predict the sample composition from spectra within seconds. Upon evaluation against more traditional peak fitting methods, we showed that these neural networks achieve competitive quantification accuracy. The proposed framework is shown to be flexible enough to accommodate spectra containing multiple chemical elements and measured with different experimental parameters. The use of dropout variational inference for the determination of quantification uncertainty is illustrated.
Related Concept Videos
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
UV–Vis Spectroscopy: Molecular Electronic Transitions
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview