Related Experiment Video
Updated: Jul 26, 2025

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Capacitively coupled contactless conductivity detection to account for system-induced gradient deformation in liquid
Leon E Niezen1, Tijmen S Bos2, Peter J Schoenmakers1
1Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands.
Abstract:
The time required for method development in gradient-elution liquid chromatography (LC) may be reduced by using an empirical modelling approach to describe and predict analyte retention and peak width. However, prediction accuracy is impaired by system-induced gradient deformation, which can be especially prominent for steep gradients. As the deformation is unique to each LC instrument, it needs to be corrected for if retention modelling for optimization and method transfer is to become generally applicable. Such a correction requires knowledge of the actual gradient profile. The latter has been measured using capacitively coupled "contactless" conductivity detection (C4D), featuring a low detection volume (approximately 0.05 μL) and compatibility with very high pressures (80 MPa or more). Several different solvent gradients, from water to acetonitrile, water to methanol, and acetonitrile to tetrahydrofuran, could be measured directly without the addition of a tracer component to the mobile phase, exemplifying the universal nature of the approach. Gradient profiles were found to be unique for each solvent combination, flowrate, and gradient duration. The profiles could be described by convoluting the programmed gradient with a weighted sum of two distribution functions. Knowledge of the exact profiles was used to improve the inter-system transferability of retention models for toluene, anthracene, phenol, emodin, sudan-I and several polystyrene standards.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

