Related Experiment Video
Updated: Jul 26, 2025

3D Whole-heart Myocardial Tissue Analysis
Published on: April 12, 2017
Exhaustive matching of 3D/2D coronary artery structure based on imperfect segmentations
Wei Wu1,2, Hongzhi Xie3, Shuyang Zhang4
1Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Purpose:
The 3D/2D coronary artery registration technique has been developed for the guidance of the percutaneous coronary intervention. It introduces the absent 3D structural information by fusing the pre-operative computed tomography angiography (CTA) volume with the intra-operative X-ray coronary angiography (XCA) image. To conduct the registration, an accurate matching of the coronary artery structures extracted from the two imaging modalities is an essential step.
Methods:
In this study, we propose an exhaustive matching algorithm to solve this problem. First, by recognizing the fake bifurcations in the XCA image caused by projection and concatenating the fractured centerline fragments, the original XCA topological structure is restored. Then, the vessel segments in the two imaging modalities are removed orderly, which generates all the potential structures to simulate the imperfect segmentation results. Finally, the CTA and XCA structures are compared pairwise, and the matching result is obtained by searching for the structure pair with the minimum similarity score.
Results:
The experiments were conducted based on a clinical dataset collected from 46 patients and comprising of 240 CTA/XCA data pairs. And the results show that the proposed method is very effective, which achieves an accuracy of 0.960 for recognizing the fake bifurcations in the XCA image and an accuracy of 0.896 for matching the CTA/XCA vascular structures.
Conclusion:
The proposed exhaustive structure matching algorithm is simple and straightforward without any impractical assumption or time-consuming computations. With this method, the influence of the imperfect segmentations is eliminated and the accurate matching could be achieved efficiently. This lays a good foundation for the subsequent 3D/2D coronary artery registration task.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022