Related Experiment Video
Updated: Jul 26, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
The accuracy and difference of scoring rules and methods to score respiratory event-related leg movements in
Yun Jin Kang1, Jae Seong An2, Jae Min Park2
1Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University College of Medicine, Cheonan, South Korea.
Objective:
To compare manual scoring: 1) to the American Academy of Sleep Medicine (AASM) auto-scoring rules. 2) to the AASM and World Association of Sleep Medicine (WASM) rules, and evaluate the accuracy of the AASM and WASM for respiratory event-related limb movements (RRLM) in diagnostic and continuous positive airway pressure (CPAP) titration polysomnography (PSG).
Methods:
We retrospectively, re-scored diagnostic and CPAP titration PSGs of 16 patients with obstructive sleep apnea (OSA), using manual re-scoring by the AASM (mAASM) and WASM (mWASM) criteria for RRLM, periodic limb movements during sleep (PLMS), and limb movements (LM), which were compared to auto-scoring by the AASM (aAASM).
Results:
In diagnostic PSG, significant differences were found in LMs (p < 0.05), RRLM (p = 0.009) and the mean duration of PLMS sequences (p = 0.013). In CPAP titration PSG, there was a significant difference in RRLM (p = 0.008) and PLMS with arousal index (p = 0.036). aAASM underestimated LM and RRLM, especially in severe OSA. Changes in RRLM and PLMS with arousal index between diagnostic and titration PSG were significantly different between aAASM and mAASM, but there was no significant difference between scoring by mAASM and mWASM. The ratio of PLMS and RRLM changes between diagnostic and CPAP titration PSG was 0.257 in mAASM and 0.293 in mWASM.
Conclusions:
In addition to the overestimation of RRLM by mAASM compared to aAASM, mAASM may also be more sensitive than aAASM in detecting RRLM changes in the titration PSG. Despite intuitive differences in the definition of RRLM between AASM and WASM rules, RRLM results between mAASM and mWASM were not significant and about 30% of RRLMs might be scored as PLMS by both scoring rules.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...