NON-ENDOSCOPIC ESOPHAGEAL SAMPLING DEVICE AND BIOMARKER PANEL FOR DETECTION OF BARRETT'S ESOPHAGUS (BE) AND
Background:
We previously reported an encapsulated balloon (EsoCheck TM , EC), which selectively samples the distal esophagus, that coupled with a two methylated DNA biomarker panel (EsoGuard TM , EG), detected Barrett's esophagus (BE) and esophageal adenocarcinoma (EAC), with a sensitivity and specificity of 90.3% and 91.7%, respectively. This previous study utilized frozen EC samples.
Aim:
To assess a next generation EC sampling device and EG assay that utilizes a room temperature sample preservative to enable office-based testing.
Methods:
Cases with nondysplastic (ND) and dysplastic (indefinite=IND, low grade dysplasia = LGD, high grade dysplasia = HGD) BE, EAC, junctional adenocarcinoma (JAC) and controls with no intestinal metaplasia (IM) were included. Nurses or physician assistants at six institutions, who were trained in EC administration, delivered the encapsulated balloon per orally and inflated it in the stomach. The inflated balloon was pulled back to sample 5 cm of the distal esophagus, then deflated and retracted into the EC capsule to prevent sample contamination from proximal esophagus. Nextgen EG sequencing assays performed on bisulfite-treated DNA extracted from EC samples determined levels of methylated Vimentin (mVIM) and methylated Cyclin A1 (mCCNA1) in a CLIA-certified laboratory, blinded to patients' phenotypes.
Results:
A total of 243 evaluable patients - 88 cases (median age 68 years, 78% men, 92% white) and 155 controls (median age 57 years, 41% men, 88% white) - underwent adequate EC sampling. Mean time for EC sampling was just over 3 minutes. The cases included 31 NDBE, 16 IND/LGD, 23 HGD, and 18 EAC/JAC. Thirty-seven (53%) of the non-dysplastic and dysplastic BE cases were short-segment BE (SSBE; < 3 cm). Overall sensitivity for detecting all cases was 85% (95% CI= 0.78-0.93) and specificity was 85% (95% CI=0.79-0.90). Sensitivity for NDBE was 84% (n=37). The EC/EG test detected 100% of cancers.
Conclusion:
The next-generation EC/EG technology has been both successfully updated to incorporate a room temperature sample collection preservative and successfully implemented in a CLIA certified laboratory. When performed by trained personnel, EC/EG detects non-dysplastic BE, dysplastic BE, and cancer with high sensitivity and specificity, replicating the operating characteristics of the initial pilot study of this technology. Future applications utilizing EC/EG to screen broader populations at risk for developing cancer are proposed.
Significance:
This multi-center study demonstrates the successful performance of a commercially available clinically implementable non-endoscopic screening test for BE in the U.S., as recommended in the most recent ACG Guideline and AGA Clinical Update. It transitions and validates a prior academic laboratory-based study of frozen research samples over to a CLIA laboratory, one that also integrates a clinically practical room temperature method for sample acquisition and storage, enabling office-based screening.
Related Concept Videos
Barrett Esophagus-I: Introduction
This constant acid exposure transforms the esophagus's pink mucosal lining (stratified squamous epithelium) into a type of lining more...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Serum Laboratory Studies, Stool Test, Breath Test
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...