Related Experiment Video
Updated: Jul 26, 2025

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
A protocol for tactile function assessment using JVP domes: Feasibility study and preliminary results
Yung-Jung Wang1,2, Chung-Tung Sung1,2, Jian-Jia Huang3,4,5
1School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Background:
Touch is a crucial sense for perceiving the spatial characteristics of objects. The JVP dome was developed to evaluate tactile spatial acuity using a grating orientation task. There were few studies depicting sequences and details for the entire task, including practice, training, and testing sessions. Therefore, we proposed and elaborated a protocol for the grating orientation task using the staircase method, which required fewer testing trials compared with the method of constant stimuli.
Methods:
Twenty-three healthy participants were enrolled in this experiment. The JVP domes with 11 different groove widths were used. Tactile discrimination thresholds were estimated using a two-down-one-up staircase method. The experiment comprised practice, training, and testing sessions, conducted by trained examiners who performed grating stimulation on participants' index fingerpads.
Results:
All participants passed the required accuracy in the practice and training sessions. Eight transition points were obtained in the testing session for each participant. The tactile discrimination thresholds were determined from the last six transition points. We obtained the mean tactile discrimination threshold as 1.8 ± 0.75 mm (n = 23). The results demonstrated that the proposed protocol was successfully applied to assess tactile discrimination thresholds.
Conclusions:
The present study investigated the protocol of grating orientation tasks requiring a small number of testing trials with the assurance of the task quality. The feasibility study and preliminary results indicated the potentiality of this protocol for future clinical application.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of the Abdomen III: Palpation
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Pulse Assessment Sites
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:

