Related Experiment Video
Updated: Jul 26, 2025

A Polyaniline-based Sensor of Nucleic Acids
Published on: November 1, 2016
Engineering Nano-Au-Based Sensor Arrays for Identification of Multiple Ni(II) Complexes in Water Samples
Ningyi Chen1,2, Shuang Wu2, Bingjun Pan2
1State Key Laboratory of Pollution Control and Resource Reuse, School of Environment, Nanjing University, Nanjing 210023, China.
Abstract:
Advanced techniques for nickel (Ni(II)) removal from polluted waters have long been desired but challenged by the diversity of Ni(II) species (most in the form of complexes) which could not be readily discriminated by the traditional analytical protocols. Herein, a colorimetric sensor array is developed to address the above issue based on the shift of the UV-vis spectra of gold nanoparticles (Au NPs) after interaction with Ni(II) species. The sensor array is composed of three Au NP receptors modified by N-acetyl-l-cysteine (NAC), tributylhexadecylphosphonium bromide (THPB), and the mixture of 3-mercapto-1-propanesulfonic acid and adenosine monophosphate (MPS/AMP), to exhibit possible coordination, electrostatic attraction, and hydrophobic interaction toward different Ni(II) species. Twelve classical Ni(II) species were selected as targets to systematically demonstrate the applicability of the sensor array under various conditions. Multiple interactions with Ni(II) species were evidenced to trigger the diverse Au NP aggregation behaviors and subsequently produce a distinct colorimetric response toward each Ni(II) species. With the assistance of multivariate analysis, the Ni(II) species, either as the sole compound or as mixtures, can be unambiguously discriminated with high selectivity in simulated and real water samples. Moreover, the sensor array is very sensitive with the detection limit in the range of 4.2 to 10.5 μM for the target Ni(II) species. Principal component analysis signifies that coordination dominates the response of the sensor array toward different Ni(II) species. The accurate Ni(II) speciation provided by the sensor array is believed to assist the rational design of specific protocols for water decontamination and to shed new light on the development of convenient discrimination methods for other toxic metals of concern.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
16:11Thermochemical Studies of NiII and ZnII Ternary Complexes Using Ion Mobility-Mass Spectrometry
Published on: June 8, 2022