Related Experiment Video
Updated: Jul 26, 2025

Yeast Luminometric and Xenopus Oocyte Electrophysiological Examinations of the Molecular Mechanosensitivity of TRPV4
Published on: December 31, 2013
FRET analysis of the temperature-induced structural changes in human TRPV3
Jinyoung Kim1, Jongdae Won1, Dong Kyu Chung1
1Department of Chemistry, College of Natural Sciences, Seoul National University, Seoul, 08826, Korea.
Abstract:
Transient receptor potential vanilloid member 3 (TRPV3) is an ion channel that plays a critical role in temperature sensing in skin. There have been active studies on how TRPV3, which is also known as one of the temperature-sensitive transient receptor potential (thermoTRP) channels, responds to temperature. However, the previous studies were mostly based on TRPV3 originating from mice or rats. Here, we focus on human TRPV3 (hTRPV3) and show that which domain of hTRPV3 undergoes conformational changes as temperature increases by Förster resonance energy transfer (FRET) assay. During the heat-induced activation of hTRPV3, the linker domain close to C-terminus, that is, the C-terminal domain shows a largest structural change whereas there is little change in the ankyrin repeat domain (ARD). Interestingly, the activation of hTRPV3 by an agonist shows structural change patterns that are completely different from those observed during activation by heat; we observe structural changes in ARD and S2-S3 linker after ligand stimulation whereas relatively little change is observed when stimulated by heat. Our results provide insight into the thermal activation of hTRPV3 channel.
Related Concept Videos
Thermosensation
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Dependent Deformation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Thermal Strain
Mechanically-gated Ion Channels