Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
High resolution electronic spectroscopy of uranium mononitride, UN
Anh T Le1, Xi-Lin Bai2, Michael C Heaven3
1School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30318, USA.
Abstract:
The isoelectronic molecules UN and UO+ are known to have Ω = 3.5 and Ω = 4.5 ground states, respectively (where Ω is the unsigned projection of the electronic angular momentum along the internuclear axis). A ligand field theory model has been proposed to account for the difference [Matthew and Morse, J. Chem. Phys. 138, 184303 (2013)]. The ground state of UO+ arises from the U3+(5f3(4I4.5))O2- configuration. Owing to the higher nominal charge of the N3- ligand, the U3+ ion in UN is stabilized by promoting one of the 5f electrons to the more polarizable 7s orbital, reducing the repulsive interaction with the ligand and rendering U3+(5f27s(4H3.5))N3- the lowest energy configuration. In the present work, we have advanced the characterization of the UN ground state through studies of two electronic transitions, [18.35]4.5-X(1)3.5 and [18.63]4.5-X(1)3.5, using sub-Doppler laser excitation techniques with fluorescence detection. Spectra were recorded under field-free conditions and in the presence of static electric or magnetic fields. The ground state electric dipole moment [μ = 4.30(2) D] and magnetic ge-factor [2.160(9)] were determined from these data. These values were both consistent with the 5f27s configurational assignment. Dispersed fluorescence measurements were used to determine vibrational constants for the ground and first electronically excited states. Electric dipole moments and magnetic ge-factors are also reported for the higher-energy electronically excited states.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
12:05U2O5 Film Preparation via UO2 Deposition by Direct Current Sputtering and Successive Oxidation and Reduction with Atomic Oxygen and Atomic Hydrogen
Published on: February 21, 2019
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
UV–Vis Spectroscopy: Molecular Electronic Transitions
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
UV–Vis Spectrometers
High-Resolution Mass Spectrometry (HRMS)
Atomic Emission Spectroscopy: Lab