Related Experiment Video
Updated: Jul 26, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
A two-staged adsorption/thermal desorption GC/MS online system for monitoring volatile organic compounds
Wenjun Wang1, Huan Chen2, Wei Zhu3
1School of Leisure Tourism, Chengdu Agricultural College, Chengdu, 611130, China.
Abstract:
Real-time online monitoring of volatile organic compounds (VOCs) in ambient air is crucial for timely and effective human health protection. Here, we developed an innovative, automated two-staged adsorption/thermal desorption gas chromatography/mass spectrometry (GC/MS) system for real-time online monitoring of 117 regulated volatile organic compounds (VOCs). This system comprised a sampling unit, water management trap, two-staged adsorption/thermal desorption unit, thermoelectric coolers (TECs), and a commercial GC/MS system. By implementing a micro-purge-and-trap (MP & T) step and a two-staged adsorption/thermal desorption unit, the presence of interfering substances was effectively minimized. The utilization of a heart-cutting GC, combined with a single MS detector, facilitated the precise separation and detection of 117 C2-C12 VOCs, while circumventing the identification and coelution challenges commonly associated with traditional GC-FID or GC-FID/MS methods. The performance of our newly developed online system was meticulously optimized and evaluated using standard gas mixtures. Under optimal conditions, we achieved impressive results, with R2 values ≥ 0.9946 for the standard linear curves of all 117 VOCs, demonstrating a precision (RSD) ranging from 0.2% to 6.4%. When applied in the field monitoring, the concentration drifts for 10 ppbv standard gas mixtures were 0.01-5.64% within 24 h. Our study developed a system for online monitoring of 117 atmospheric VOCs with relatively high accuracy and robustness.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...