Related Experiment Video
Updated: Jul 25, 2025

Development of a 68Gallium-Labeled D-Peptide PET Tracer for Imaging Programmed Death-Ligand 1 Expression
Published on: February 3, 2023
PD-L1 ImmunoPET on the basis of Avidin/Biotin pre-targeted cancer imaging
Zhongqiu Guo1, Lizhi Zhu1, Wen Xu2
1Department of Nuclear Medicine, Shanghai Changhai Hospital, Shanghai, 200433, China.
This study aimed to establish the radio-immune imaging protocol on the basis of Avidin/Biotin system. The programmed death-ligand 1 (PD-L1) antibody (Atezolizumab) was employed as the primary molecule in targeting PD-L1, and the two-step strategy, consisting of the first injection of Avidin-conjugated PD-L1 monoclonal antibody (Atezolizumab) and the second injection of 7.4 MBq 68Ga-Biotin with a 60 h interval, was then verified on the colon cancer-bearing mice. PET imaging was performed at 30, 90, 180 min to measure the standard uptake value and tumor to liver ratios. Cellular binding experiments and in vivo distribution showed that the conjugation of Avidin did not affect the affinity of Atezolizumab to PD-L1 antigen. Biotin was radio-labeled with 68Ga with radiolabeling efficiency of 70.5 ± 3.5% and purification was needed to increase the radiochemical purity. For PD-L1-positive tumors, SUVmax was 0.38 ± 0.06 in the Avidin-Atezolizumab pre-treated mice at 90 min; the tumor/liver ratios of pre-targeting group were 1.06 ± 0.19 and 0.97 ± 0.16 at 30 and 90 min, while the absence of pre-treatment of Avidin was of the lower ratios as 0.88 ± 0.01 and 0.54 ± 0.11 when 68Ga-Biotin served as the radiopharmaceutical as well. In conclusion, pre-targeting immunoPET strategy can elevate the target-to-nontarget ratio, decrease the blood background and shorten the interval between injection of radiopharmaceuticals and PET scan, providing a highly PD-L1-specific and sensitive imaging method for the detection of tumorous immune micro-environment.
This study aimed to establish the radio-immune imaging protocol on the basis of Avidin/Biotin system. The programmed death-ligand 1 (PD-L1) antibody (Atezolizumab) was employed as the primary molecule in targeting PD-L1, and the two-step strategy, consisting of the first injection of Avidin-conjugated PD-L1 monoclonal antibody (Atezolizumab) and the second injection of 7.4 MBq 68Ga-Biotin with a 60 h interval, was then verified on the colon cancer-bearing mice. PET imaging was performed at 30, 90, 180 min to measure the standard uptake value and tumor to liver ratios. Cellular binding experiments and in vivo distribution showed that the conjugation of Avidin did not affect the affinity of Atezolizumab to PD-L1 antigen. Biotin was radio-labeled with 68Ga with radiolabeling efficiency of 70.5 ± 3.5% and purification was needed to increase the radiochemical purity. For PD-L1-positive tumors, SUVmax was 0.38 ± 0.06 in the Avidin-Atezolizumab pre-treated mice at 90 min; the tumor/liver ratios of pre-targeting group were 1.06 ± 0.19 and 0.97 ± 0.16 at 30 and 90 min, while the absence of pre-treatment of Avidin was of the lower ratios as 0.88 ± 0.01 and 0.54 ± 0.11 when 68Ga-Biotin served as the radiopharmaceutical as well. In conclusion, pre-targeting immunoPET strategy can elevate the target-to-nontarget ratio, decrease the blood background and shorten the interval between injection of radiopharmaceuticals and PET scan, providing a highly PD-L1-specific and sensitive imaging method for the detection of tumorous immune micro-environment.

