Related Experiment Video
Updated: Jul 25, 2025

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Discordances Between Creatinine- and Cystatin C-Based Estimated GFR and Adverse Clinical Outcomes in Routine Clinical
Juan-Jesús Carrero1, Edouard L Fu2, Yingying Sang3
1Department of Medical Epidemiology and Biostatistics, Karolinska Institutet, Stockholm, Sweden; Division of Nephrology, Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
Rationale & Objective:
Cystatin C is recommended for measuring estimated glomerular filtration rate (eGFR) when estimates based on creatinine (eGFRcr) are not thought to be accurate enough for clinical decision making. While global adoption is slow, routine cystatin C testing in Sweden has been available for over a decade, providing real-world evidence about the magnitude of differences between eGFRcys and eGFRcr and their association with clinical outcomes.
Study Design:
Observational study.
Setting & Participants:
158,601 adults (48% women; mean age 62 years, eGFRcr 80, and eGFRcys 73mL/min/1.73/m2) undergoing testing for creatinine and cystatin C on the same day in connection with a health care encounter during 2010-2018 in Stockholm, Sweden.
Exposure:
Percentage difference of eGFRcys minus eGFRcr (eGFRdiff).
Outcome:
Kidney failure with replacement therapy (KFRT), acute kidney injury (AKI), atherosclerotic cardiovascular disease (ASCVD), heart failure, and death.
Analytical Approach:
Multivariable Cox proportional hazards regression.
Results:
Discordances between eGFRcr and eGFRcys were common, with eGFRcys being lower than eGFRcr (negative eGFRdiff) in most cases (65%). Patients with larger negative eGFRdiff were older, more often female, with higher eGFRcr and albuminuria, and more comorbid conditions. Compared with patients with similar eGFRcys and eGFRcr, the lowest quartile (eGFRcys > 27% lower than eGFRcr) had the higher HR of all study outcomes: AKI, 2.6 (95% CI, 2.4-2.9); KFRT, 1.4 (95% CI, 1.2-1.6); ASCVD, 1.4 (95% CI, 1.3-1.5); heart failure, 2.0 (95% CI, 1.9-2.2); and all-cause death, 2.6 (95% CI, 2.5-2.7). Conversely, patients in the highest quartile (positive eGFRdiff) were at lower risk.
Limitations:
Observational study, lack of information on indications for cystatin C testing.
Conclusions:
Cystatin C testing in routine care shows that many patients have a lower eGFRcys than eGFRcr, and these patients have a higher risk of multiple adverse outcomes.
Plain-Language Summary:
Clinicians require guidance when there are discrepancies between the estimated glomerular filtration rate based on creatinine (eGFRcr) and based on cystatin C (eGFRcys) in the same individual. Routine cystatin C testing in Sweden for over a decade permits exploration of how common and large these discrepancies are, and their associations with adverse clinical outcomes. In this observational study, we found that discordances between eGFRcys and eGFRcr are common, and 1 in 4 patients tested had an eGFRcys > 28% lower than their eGFRcr. We also show that an eGFRcys that is lower than the eGFRcr consistently identifies patients at higher risk of adverse outcomes, including cardiovascular events, kidney replacement therapy, acute kidney injury, and death.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Serum Studies: Renal Function Tests
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...