Predicting Catalyst Extrudate Breakage Based on the Modulus of Rupture
Published on: May 13, 2018
Comparing failure tests on pharmaceutical tablets: Interpretation using experimental results and a numerical approach
Vincent Mazel1, Jérémie Girardot2, Jean-Benoit Kopp2
1Univ. Bordeaux, Arts et Metiers Institute of Technology, University of Bordeaux, CNRS, Bordeaux INP, INRAe, I2M Bordeaux, 33400 Talence, France.
Discrepancies in pharmaceutical tablet tensile strength (TS) measurements arise from using the maximum stress criterion. A cohesive zone model (CZM) better predicts tablet fracture, aligning numerical and experimental results.
Area of Science:
- Pharmaceutical Sciences
- Materials Science
- Mechanical Engineering
Background:
- Mechanical strength is a critical quality attribute for pharmaceutical tablets.
- Standard failure tests like the Brazilian test and three-point bending test are used to determine tensile strength (TS).
- Literature reports conflicting TS values from different tests, often attributed to the maximum stress criterion.
Purpose of the Study:
- To investigate the discrepancies in TS values obtained from different failure tests for pharmaceutical tablets.
- To test the hypothesis that the maximum stress criterion is unsuitable for heterogeneous and quasi-brittle pharmaceutical tablets.
- To implement and calibrate a numerical fracture criterion, the cohesive zone model (CZM), as an alternative.
Main Methods:
- Experimental calibration of the cohesive zone model (CZM) using tablet failure tests.
- Numerical simulations employing the calibrated CZM to predict tablet breaking forces.
- Comparison of numerical results with experimental data and literature findings.
Main Results:
- Numerical breaking forces using the CZM showed good agreement with experimental values.
- The CZM approach successfully captured the trends observed when comparing different failure tests.
- The model reproduced the factor of 2 difference in TS between three-point bending and diametral compression tests found in literature.
Conclusions:
- The maximum stress criterion is inadequate for accurately assessing the tensile strength of pharmaceutical tablets due to stress heterogeneity and their quasi-brittle nature.
- The cohesive zone model (CZM) provides a more suitable numerical approach for evaluating pharmaceutical tablet mechanical strength.
- The CZM can reconcile discrepancies in TS measurements from different testing methods, improving the reliability of tablet mechanical property assessment.
Related Concept Videos
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model
Model Approaches for Pharmacokinetic Data: Compartment Models
Two primary types of compartment models are recognized: mammillary and catenary. The more...
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal...
Mechanistic Models: Overview of Compartment Models