Related Experiment Video
Updated: Jul 25, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Durability of Biological Valves Implanted in Aortic or Mitral Positions: A Nationwide Cohort Study
Chun-Yu Chen1, Chia-Pin Lin2, Kuo-Chun Hung2
1Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan; Department of Medicine, College of Medicine, Chang Gung University, Taoyuan City, Taiwan.
Background:
Biologic prostheses are being increasingly used for aortic and mitral valve replacement (AVR and MVR). This study evaluated the long-term durability of bioprosthetic valves in the mitral and aortic positions, as no well-designed population-based studies have addressed this issue before.
Methods:
Using Taiwan's National Health Insurance Research Database, we compared biologic valve durability in the mitral and aortic positions in patients hospitalized between 2001 and 2017, with reoperation as the primary outcome. Both between-subject and within-subject designs were used, and the propensity score matching cohort (1:1 ratio) was created for the former.
Results:
We identified a total of 10,308 patients, 5462 of whom received AVR, 3901 received MVR, and 945 received double valve replacement. Both AVR and MVR cohorts had 2259 patients after matching. During a mean follow-up of 4.2 years (range, 1 day to 17.9 years), the reoperation rate in the MVR cohort (3.5%) was higher than that in the AVR cohort (2.6%) (hazard ratio 1.41; 95% CI, 1.01-1.98). A higher risk of all-cause death was observed in the MVR cohort (36.5%) than in the AVR cohort (32.6%) (hazard ratio 1.21; 95% CI, 1.10-1.34). Among patients receiving double valve replacement with the same prosthesis type, valves implanted in the aortic position were considerably less likely to require reimplantation.
Conclusions:
Bioprosthetic valve placement in the aortic position is associated with superior outcomes in terms of durability, long-term mortality, and perioperative morbidity. Developing novel interventions and enhancing valve durability would expand bioprosthesis use for valve replacement.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Stenosis III: Medical Management
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation III: Medical Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests