Patients' Radiation Exposure During Endovascular Abdominal Aortic Aneurysm Repair
Tim J Mandigers1, Irene Fulgheri2, Giorgia Pugliese3
1Vascular Surgery Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
Background:
To investigate associations between patient characteristics, intraprocedural complexity factors, and radiation exposure to patients during endovascular abdominal aortic aneurysm repair (EVAR).
Methods:
Elective standard EVAR procedures between January 2015 and December 2020 were retrospectively analyzed. Patient characteristics and intraprocedural data (i.e., type of device, endograft configuration, additional procedures, and contralateral gate cannulation time [CGCT]) were collected. Dose area product (DAP) and fluoroscopy time were considered as measurements of radiation exposure. Furthermore, effective dose (ED) and doses to internal organs were calculated using PCXMC 2.0 software. Descriptive statistics, univariable, and multivariable linear regression were applied to investigate predictors of increased radiation exposure.
Results:
The 99 patients were mostly male (90.9%) with a mean age of 74 ± 7 years. EVAR indications were most frequently abdominal aortic aneurysm (93.9%), penetrating aortic ulceration (2.0%), focal dissection (2.0%), or subacute rupture of infrarenal abdominal aortic aneurysm (2.0%). Median fluoroscopy time was 19.6 minutes (interquartile range [IQR], 14.1-29.4) and median DAP was 86,311 mGy cm2 (IQR, 60,160-130,385). Median ED was 23.2 mSv (IQR, 17.0-34.8) for 93 patients (93.9%). DAP and ED were positively correlated with body mass index (BMI) and CGCT. Kidneys, small intestine, active bone marrow, colon, and stomach were the organs that received the highest equivalent doses during EVAR. Higher DAP and ED values were observed using the Excluder endograft, other bi- and tri-modular endografts, and EVAR with ≥2 additional procedures. Multivariable linear regression analysis revealed that BMI, ≥2 additional procedures during EVAR, and CGCT were independent positive predictors of DAP and ED levels after accounting for endograft type.
Conclusions:
Patient-related and procedure-related factors such as BMI, ≥2 additional procedures during EVAR, and CGCT resulted predictors of radiation exposure for patients undergoing EVAR, as quantified by higher DAP and ED levels. The main intraprocedural factor that increased radiation exposure was CGCT. These data can be of importance for better managing radiation exposure during EVAR.
Related Concept Videos
Aneurysm IV: Nursing Management
Aneurysm III: Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Peripheral Artery Disease V: Postoperative Nursing Management
Imaging Studies VII: Vascular Imaging
Aneurysm II: Clinical Manifestations and Diagnostic Studies