Related Experiment Video
Updated: Jul 25, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Method development for the intraoral release of nanoparticles from dental restorative materials
Laura Kleinvogel1, Gregor Wemken1, Cosima Reidelbach2
1Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Centre - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
Objective:
The aim of this study was the development of a novel in-vitro method to evaluate the intraoral release of wear particles with a diameter< 1 µm from dental restorative materials.
Methods:
Test fixtures for a dual-axis chewing simulator (CS-4.8, SD Mechatronik, Feldkirchen-Westerham, Germany), consisting of three components to mount the specimens and a solvent (distilled water) as well as a zirconia antagonist to transfer the masticatory forces onto the specimen was developed. Ceram.x Spectra™ ST HV (CS) and Filtek™ Supreme XTE (FS) specimens (n = 3) were fixed into the mounts and immersed in 25 ml solvent. All specimens were subjected to 500.000 wear cycles with a load of 49 N. The particle size distribution of the suspensions were examined by dynamic light scattering (DLS). The collected particles were characterised by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For wear quantification, the surfaces of the specimens were photo-optically scanned and the wear was measured. For the statistical analysis, one-way ANOVA and post-hoc Scheffé tests were applied.
Results:
DLS showed particle diameters< 1 µm (CS: 18.06 nm-1.64 µm, FS: 72.30 nm-2.31 µm). SEM/EDS indicated an association between the detected elements and the materials' composition. FS showed significantly higher volume loss (p = 0.007) and maximum depth of the wear profile (p = 0.005) than CS, but no significant differences in the surface loss (p = 0.668).
Significance:
The novel method is able to detect material dependent particles to the size of nanoscale after in-vitro abrasion.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins