Purpose:
To compare corneal power difference maps (∆maps) obtained from the Pentacam in patients with 1 year follow-up after LASIK, PRK, and SMILE with further stratification to low, moderate, and high myopia.
Patients And Methods:
This retrospective study was comprised of patients who had preoperative and 1-year postoperative power maps that were obtained-front sagittal (SagF), refractive power (RP), true net power (TNP), and total corneal refractive power (TCRP)-for evaluation. Measurements were recorded and compared at the 4mm, 5mm and 6mm pupil and apex zones. Comparisons were made between each specific power ∆map and the surgically induced refractive change (SIRC). Further analysis of the ∆maps was performed based on degree of myopia (high, moderate, and low). Correlation and agreement were also assessed with regression and limits of agreement (LoA).
Results:
There were 172 eyes in the LASIK group, 187 eyes in the PRK group, and 46 eyes in the SMILE group. In the LASIK group, TNP ∆map at 5mm pupil zone had the least absolute mean difference with SIRC (0.007 ± 0.42D). In the PRK group, TNP ∆map at 5mm apex zone was most accurate compared to SIRC (0.066 ± 0.45D). In the SMILE group, TCRP ∆map at 4mm apex zone had the closest absolute value when compared to SIRC (0.011 ± 0.50D). There was good correlation and agreement for all three surgery groups, LASIK: r = 0.975, LoA -0.83D to +0.83D, PRK: r = 0.96, LoA -0.83D and +0.95D, and SMILE: r = 0.922, LoA -0.97 D to +0.99D.
Conclusion:
TNP ∆maps most accurately measured corneal power in the LASIK and PRK groups while TCRP ∆maps were most accurate in the SMILE group. The degree of myopia may change which ∆map is most accurate.