Related Experiment Video
Updated: Jul 25, 2025

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Oxygenation target in acute respiratory distress syndrome
Gilles Capellier1,2,3, Loic Barrot1,4, Hadrien Winizewski1,3
1Réanimation Médicale, CHU Jean Minjoz, Besançon 25000, France.
Abstract:
Determining oxygenation targets in acute respiratory distress syndrome (ARDS) remains a challenge. Although oxygenation targets have been used since ARDS was first described, they have not been investigated in detail. However, recent retrospective and prospective trials have evaluated the optimal oxygenation threshold in patients admitted to the general intensive care unit. In view of the lack of prospective data, clinicians continue to rely on data from the few available trials to identify the optimal oxygenation strategy. Assessment of the cost-benefit ratio of the fraction of inspired oxygen (FiO2) to the partial pressure of oxygen in the arterial blood (PaO2) is an additional challenge. A high FiO2 has been found to be responsible for respiratory failure and deaths in numerous animal models. Low and high PaO2 values have also been demonstrated to be potential risk factors in experimental and clinical situations. The findings from this literature review suggest that PaO2 values ranging between 80 mmHg and 90 mmHg are acceptable in patients with ARDS. The costs of rescue maneuvers needed to reach these targets have been discussed. Several recent papers have highlighted the risk of disagreement between arterial oxygen saturation (SaO2) and peripheral oxygen saturation (SpO2) values. In order to avoid discrepancies and hidden hypoxemia, SpO2 readings need to be compared with those of SaO2. Higher SpO2 values may be needed to achieve the recommended PaO2 and SaO2 values.
More Related Videos
04:10Author Spotlight: Exploring Venous Waveforms for Non-Invasive Respiratory Monitoring in Pigs
Published on: March 8, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...