Opioid cutting agents for use as internal standards in ion mobility spectrometry (IMS)
Charles D Smith1, Braden C Giordano1
1U.S. Naval Research Laboratory, 4555 Overlook Ave SW, Washington, D.C, 20375, United States.
None:
Opioids have become a serious public health concern over the last decade. These compounds are commonly found mixed, or cut, with safer compounds to make the opioids appear unadulterated while also enhancing the psychoactive effect on the user. Commercial benchtop and handheld IMS devices are capable of detection but published reduced ion mobility (K0) values, used to identify the target analytes with IMS instrumentation, have shown variability. This lack of agreement, even for compounds used for calibration, is often due to the effects of drift tube temperature, drift gas water vapor levels and the use in-house built instrumentation rather than commercial equipment. Multiple reports exist on assessment of IMS reference standards but a single, consensus universal standard does not exist. Assessment of opioid cutting agents as internal standards is a worthwhile pursuit if precise and accurate K0 values are obtained. The effects of drift gas water vapor content and drift tube temperature were used to evaluate the cutting agents. The K0 values of papaverine, a representative opioid with a similar K0 value to heroin and fentanyl, were calculated with respect to quinine and were in agreement with literature data. The use of quinine as an internal standard also improved precision relative to the instrument standard and shows promise in the application presented here.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
High-Resolution Mass Spectrometry (HRMS)