Impact of log file source and data frequency on accuracy of log file-based patient specific quality assurance
Akbar Azzi1, Gerd Heilemann2, Dietmar Georg2
1Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, 16424 Depok, Indonesia.
Abstract:
Performing phantom measurements for patient-specific quality assurance (PSQA) adds a significant amount of time to the adaptive radiotherapy procedure. Log file based PSQA can be used to increase the efficiency of this process. This study compared the dosimetric accuracy of high-frequency linear accelerator (Linac) log files and low-frequency log data stored in the oncology information system (OIS). Thirty patients were included, that were recently treated in the head and neck (HN), brain, and prostate region with volumetric modulated arc therapy (VMAT) and an additional ten patients treated using stereotactic body radiation therapy (SBRT) with 3D-conformal radiotherapy (3D-CRT) technique. Log data containing a single fraction were used to calculate the dose distributions. The dosimetric differences between Linac log files and OIS logs were evaluated with a gamma analysis with 2%/2 mm criterion and dose threshold of 30%. The original treatment plan was used as a reference. Moreover, DVH parameters of D98%, D50%, and D2% of the planning-target volume (PTV) and dose to several organs at risk (OARs) were reported. Significant differences in dose distributions between the two log types and the original dose were observed for PTV D98% and D2% (r < 0.001) for HN cases, PTV D98% (r = 0.005) for brain cases, and PTV D50% (r = 0.015) for prostate cases. No significant differences were found between the two log types with respect to D50%. The root mean square (RMS) error of the leaf positions of the OIS log was approximately twice the RMS error of the Linac log file for VMAT plans, but identical for 3D-CRT plans. The relationship between the gamma pass rate and the RMS error showed a moderate correlation for the Linac log files (r = -0.58, p < 0.001) and strong correlation for OIS logs (r = -0.71, p < 0.001). Furthermore, all doses calculated using Linac log files and OIS log data had a GPR >90% for an RMS error < 3.3 mm. Based on these findings, a tolerance limit of RMS error of 3.3 mm for considering OIS log based PSQA was established. Nevertheless, the OIS log data quality should be improved to achieve adequate PSQA.
Related Concept Videos
Purpose of Health Records I
Here's a breakdown of how health records serve these purposes:
Data Reporting and Recording
Errors occurring during blood pressure monitoring
Several factors...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Introduction to Documentation and Reporting
Nursing documentation records essential information and details regarding a patient's care and treatment in written or electronic form. It is a critical aspect of nursing practice that involves documenting assessments, interventions, outcomes, and other relevant details about a patient's health status.
Documentation maps the patient's health journey by creating a comprehensive...