Related Experiment Video
Updated: Jul 25, 2025

Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
Diagnostic utility of different dysphagia screening tools to detect dysphagia in individuals with amyotrophic lateral
Xiaoqian Xia1, Wei Zhang2, Junhong Guo1
1Department of Neurology, First Hospital, Shanxi Medical University, No.85, Jiefang South Street, Taiyuan, China.
Objective:
Dysphagia is a common and serious clinical symptom of amyotrophic lateral sclerosis (ALS). The study aimed to evaluate the diagnostic utility of four dysphagia screening tools in ALS, including the ALS Functional Rating Scale-Revised (ALSFRS-R) bulbar subscale, water-swallowing test (WST), Eating Assessment Tool-10 (EAT-10) and Sydney Swallow Questionnaire (SSQ).
Methods:
A total of 68 individuals from First Hospital, Shanxi medical university, were recruited in the study. The ALSFRS-R, WST, EAT-10, SSQ and the gold standard video fluoroscopic swallowing study (VFSS) were performed. The Penetration Aspiration Scale (PAS) during VFSS was assessed to identify unsafe swallowing (PAS ≥ 3) and aspiration (PAS ≥ 6). Receiver operator characteristic curve (ROC) analyses were performed to evaluate the accuracy of the 4 tools. Youden index was used to determine the ideal cut-off value for each tool.
Results:
Of the patients, 20.59% (14/68) presented unsafety swallowing and 16.18% (11/68) had aspiration. The four tools could effectively identify patients with unsafe swallowing and aspiration. The EAT-10 had the maximum AUC (0.873 and 0.963, respectively) among the tools in the diagnosis of unsafe swallowing and aspiration. To detect unsafe swallowing and aspiration, an EAT-10 score of 6 (sensitivity: 78.6%, specificity: 87.0%) and an EAT-10 score of 8 (sensitivity: 90.9%, specificity: 91.2%), were the most appropriate cut-off points, respectively.
Conclusions:
The ALSFRS-R bulbar subscale, WST, EAT-10, and SSQ could effectively identify unsafe swallowing and aspiration in patients with ALS. Of the four tools, the EAT-10 was relatively accurate, safe, and convenient. Further studies including more patients should be conducted to verify the conclusions.
More Related Videos
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):