Related Experiment Video
Updated: Jul 25, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
In silico fatigue performance of molars restored with full crowns under alternating cyclic loadings
Jingang Jiang1, Jianpeng Sun2, Hongyuan Ma3
1Robotics & Its Engineering Research Center, Harbin University of Science and Technology, Harbin, 150080, PR China; Key Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin, 150080, Heilongjiang, PR China.
Objective:
In this study, a preclinical approach was used to analyze and directly compare the fatigue performance (fatigue life and damage percentage) and maximum principal stresses (Max. Ps) of prepared models treated with different materials and geometric parameters.
Methods:
Four groups of preparative parameters (crown width, crown length, degree of polymerization and material) were selected, each with five variables. An alternating cyclic occlusal load with an amplitude of 300 N was applied to the ball part along the longitudinal axis. The fatigue properties of the preparations and Max.Ps were analyzed.
Results:
A shoulder width of 0.8 mm, a shoulder height offset of 0.2 mm, a degree of polymerization of 5°, and a crown material of ZC resulted in the smallest percentage of damage. In contrast, the effect of different modulus of elasticity (MOE) on Max.Ps was not significant (p = 0.609).
Conclusion:
The results suggest that the selection of larger modulus of elasticity MOE and larger Poisson's ratio material's, preparation of larger shoulder widths within safety, reasonable increase in crown length, and selection of larger degree of polymerization are favorable methods to protect the preparation.
More Related Videos
Related Concept Videos
Fatigue
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Fatigue Strength of Concrete