Related Experiment Video
Updated: Jul 25, 2025

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Reference Standards for Digital Infrared Thermography Measuring Surface Temperature of the Upper Limbs
Seong Son1, Byung Rhae Yoo1, Ho Yeol Zhang2
1Department of Neurosurgery, Gil Medical Center, Gachon University College of Medicine, Incheon 21565, Republic of Korea.
Abstract:
(1) Background: although digital infrared thermographic imaging (DITI) is used for diverse medical conditions of the upper limbs, no reference standards have been established. This study aims to establish reference standards by analyzing DITI results of the upper limbs. (2) Methods: we recruited 905 healthy Korean adults and conducted thermography on six regions (dorsal arm, ventral arm, lateral arm, medial arm, dorsal hand, and ventral hand region). We analyzed the data based on the proximity of regions of interest (ROIs), sex, and age. (3) Results: the average temperature (°C) and temperature discrepancy between the right and the left sides (ΔT) of each ROI varied significantly (p < 0.001), ranging from 28.45 ± 5.71 to 29.74 ± 5.14 and from 0.01 ± 0.49 to 0.15 ± 0.62, respectively. The temperature decreased towards the distal ROIs compared to proximal ROIs. The average temperatures of the same ROIs were significantly higher for men than women in all regions (p < 0.001). Across all regions, except the dorsal hand region, average temperatures tended to increase with age, particularly in individuals in their 30s and older (p < 0.001). (4) Conclusions: these data could be used as DITI reference standards to identify skin temperature abnormalities of the upper limbs. However, it is important to consider various confounding factors, and further research is required to validate the accuracy of our results under pathological conditions.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
08:16Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.