Related Experiment Video
Updated: Jul 25, 2025

Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Machine Learning Techniques for the Performance Enhancement of Multiple Classifiers in the Detection of
Sivamani Palanisamy1, Harikumar Rajaguru2
1Department of Electronics and Communication Engineering, Jansons Institute of Technology, Coimbatore 641659, India.
Abstract:
Photoplethysmography (PPG) signals are widely used in clinical practice as a diagnostic tool since PPG is noninvasive and inexpensive. In this article, machine learning techniques were used to improve the performance of classifiers for the detection of cardiovascular disease (CVD) from PPG signals. PPG signals occupy a large amount of memory and, hence, the signals were dimensionally reduced in the initial stage. A total of 41 subjects from the Capno database were analyzed in this study, including 20 CVD cases and 21 normal subjects. PPG signals are sampled at 200 samples per second. Therefore, 144,000 samples per patient are available. Now, a one-second-long PPG signal is considered a segment. There are 720 PPG segments per patient. For a total of 41 subjects, 29,520 segments of PPG signals are analyzed in this study. Five dimensionality reduction techniques, such as heuristic- (ABC-PSO, cuckoo clusters, and dragonfly clusters) and transformation-based techniques (Hilbert transform and nonlinear regression) were used in this research. Twelve different classifiers, such as PCA, EM, logistic regression, GMM, BLDC, firefly clusters, harmonic search, detrend fluctuation analysis, PAC Bayesian learning, KNN-PAC Bayesian, softmax discriminant classifier, and detrend with SDC were utilized to detect CVD from dimensionally reduced PPG signals. The performance of the classifiers was assessed based on their metrics, such as accuracy, performance index, error rate, and a good detection rate. The Hilbert transform techniques with the harmonic search classifier outperformed all other classifiers, with an accuracy of 98.31% and a good detection rate of 96.55%.
More Related Videos
07:35Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
Published on: October 11, 2018
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System IV: CMRI
Cardiomyopathy I: Introduction and Classification