Analysis of the Maximum Efficiency and the Maximum Net Power as Objective Functions for Organic Rankine Cycles
Johan González1, José Matías Garrido2, Héctor Quinteros-Lama1
1Departamento de Tecnologías Industriales, Faculty of Engineering, Universidad de Talca, Merced 437, Curicó 3340000, Chile.
Abstract:
Maximum efficiency and maximum net power output are some of the most important goals to reach the optimal conditions of organic Rankine cycles. This work compares two objective functions, the maximum efficiency function, β, and the maximum net power output function, ω. The van der Waals and PC-SAFT equations of state are used to calculate the qualitative and quantitative behavior, respectively. The analysis is performed for a set of eight working fluids, considering hydrocarbons and fourth-generation refrigerants. The results show that the two objective functions and the maximum entropy point are excellent references for describing the optimal organic Rankine cycle conditions. These references enable attaining a zone where the optimal operating conditions of an organic Rankine cycle can be found for any working fluid. This zone corresponds to a temperature range determined by the boiler outlet temperature obtained by the maximum efficiency function, maximum net power output function, and maximum entropy point. This zone is named the optimal temperature range of the boiler in this work.
Related Concept Videos
Efficiency of The Carnot Cycle
The Carnot Cycle
What could be the theoretical limit to the efficiency of a heat engine? The...
The Carnot Cycle and the Second Law of Thermodynamics
Since the individual steps in a Carnot cycle can be reversed, the entire cycle is, thus, reversible. If a Carnot cycle is reversed, it becomes a Carnot refrigerator. It extracts heat Qc from a cold reservoir at...
Potential-Energy Criterion for Equilibrium
Otto and Diesel Cycle
Maximum Power Transfer
By substituting the entire circuit with...