Biomechanical Comparison of Medio-Plantar and Plantar Plate Fixation for First Tarsometatarsal Joint Arthrodesis
Kajetan Klos1,2, Paul Simons3, Pauline Schopp1
1Department of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Abstract:
Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with respect to the tibialis anterior tendon, a medio-plantar plate was developed. The purpose of this biomechanical study was to compare its construct stability to that of a plantar plate construct. Twelve pairs of fresh frozen human specimens were used in a matched pair test. Each pair was fixed with a 4 mm compression screw and either a plantar locking plate or a medio-plantar locking plate. A cantilever beam test was performed in dorsiflexion. Before and after cyclic loading (5000 cycles; 40 N), bending stiffness and relative movements at the joint space were monitored in a quasi-static test including optical motion tracking. Maximum load and bending moment to failure were investigated in a load-to-failure ramp test. The bending stiffness of both groups did not significantly differ before (plantar 49.9 N/mm ± 19.2; medio-plantar 53.9 N/mm ± 25.4, p = 0.43) or after (plantar 24.4 N/mm ± 9.7; medio-plantar 35.3 N/mm ± 22.0, p = 0.08) cyclic loading but decreased significantly in both groups (p < 0.01) after cyclic loading. Relative movement increased significantly during cyclic testing in both groups (p < 0.01) but did not differ significantly between the groups before (p = 0.29) or after (p = 0.16) cyclic loading. Neither load nor bending moment to failure were significantly different (plantar 225 N ± 78, 10.8 Nm; medio-plantar 210 N ± 86, 10.1 Nm, p = 0.61). Both plate constructs provided equivalent construct stability, both being well suited for Lapidus arthrodesis.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019