Related Experiment Video
Updated: Jul 25, 2025

Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
The Early Effects on Tricuspid Annulus and Right Chambers Dimensions in Successful Tricuspid Valve Bicuspidization
Gintarė Bieliauskienė1, Ieva Kažukauskienė1, Vilius Janušauskas1
1Clinic of Cardiovascular Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, M. K. Čiurlionio 21, 03101 Vilnius, Lithuania.
Background:
It is unclear to what degree of tricuspid annulus (TA) reduction is necessary to achieve good postoperative results in surgical bicuspidization. The study aimed to evaluate TA and right heart chamber's dimensions before and after heart surgery; and to compare TA parameters assessed by different modalities.
Methods:
Forty patients underwent mitral valve surgery with or without concomitant tricuspid valve (TV) bicuspidization. Preoperative and postoperative measurements of TA dimensions were performed prospectively using two-dimensional (2D) and three-dimensional (3D) transthoracic echocardiography (TTE). Additionally, preoperative transesophageal echocardiography (TOE) was performed in the operating room prior to surgery.
Results:
All patients had no or mild TR immediately after surgery. There was a significant reduction in 2D and 3D parameters of the TV and right chambers in the TV bicuspidization group. However, TV leaflets' tethering parameters did not change significantly. Preoperative 3D TTE measurements were smaller than those obtained through 3D TOE in the operation room, before surgery under general anesthesia. The 2D systolic apical 4Ch diameter and the parasternal short axis diameter mainly represent the 3D minor axis of the TA and are smaller than its 3D major axis.
Conclusions:
Although bicuspidization results in a one-third reduction of the TV area, tethering of the TV leaflets remains unchanged. Moreover, 3D TOE parameters of the TV under general anesthesia are larger than preoperative 3D TTE measurements. Conventional 2D measurements are insufficient for evaluating the maximum diameter of the TA.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...