Related Experiment Video
Updated: Jul 25, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Seismic Performance and Nonlinear Strain Analysis of Mechanical Splices for High-Strength Reinforcement in Concrete
Hung-Jen Lee1, Tzu-Yu Chang1, Chien-Chung Chen2
1Department of Civil and Construction Engineering, National Yunlin University of Science and Technology in Taiwan, Yunlin 640301, Taiwan.
Abstract:
This study investigates the strain development in reinforcing bars within the plastic hinge regions of beams and columns, with the main objective of modifying the current acceptance criteria for mechanical bar splices to accommodate high-strength reinforcement. The investigation utilizes numerical analysis based on moment-curvature and deformation analysis of typical beam and column sections in a special moment frame. The results indicate that the use of higher grade reinforcement, such as Grade 550 or 690, results in lower strain demands in the plastic hinge regions compared to Grade 420 reinforcement. To validate the modified seismic loading protocol, over 100 samples of mechanical coupling systems were tested in Taiwan. The test results demonstrate that the majority of these systems can successfully complete the modified seismic loading protocol and are suitable for use in critical plastic hinge regions of special moment frames. However, caution is advised for slender mortar-grouted coupling sleeves, as they were unable to fulfill the seismic loading protocols. These sleeves may be conditionally used in plastic hinge regions of precast columns, provided they meet specific conditions and demonstrate seismic performance through structural testing. The findings of this study offer valuable insight into the design and application of mechanical splices in high-strength reinforcement scenarios.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Relation Between Tensile Strength and Compressive Strength of Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Reinforcements in Concrete