Research Progress and Future Trends of Low Temperature Plasma Application in Food Industry: A Review

Jiacheng Zhang1, Qijing Du1, Yongxin Yang1,2

  • 1College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China.

PubMed

Related Concept Videos

Physical Methods for Controlling Microbial Growth: Temperature01:23

Physical Methods for Controlling Microbial Growth: Temperature

Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
149
Factors Influencing Microbial Growth: Temperature01:27

Factors Influencing Microbial Growth: Temperature

Microorganisms display remarkable adaptations, enabling them to thrive in diverse ecological niches across a wide range of temperatures. Temperature profoundly influences microbial growth by affecting enzymatic activity, membrane fluidity, and other cellular processes.Each microorganism operates within a specific temperature range defined by three cardinal points: minimum, optimum, and maximum. Below the minimum temperature, membranes lose fluidity, halting transport processes. Above the...
69
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
138
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
711
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
205