Related Experiment Video
Updated: Jul 25, 2025

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
Vascular response to the microcirculation in the fingertip by local vibration with varied amplitude
Lizhong Mu1,2, Aoran Sun1, Youqiang Chen1
1Key Laboratory of Marine Energy Utilization and Energy Conservation, School of Energy and Power, Dalian University of Technology, Dalian, China.
Abstract:
Objectives: We investigated the effect of local vibration intensity on the vascular response to the microcirculation of the finger. Materials and methods: We performed hand-transmitted vibration experiments combined with laser Doppler flowmetry (LDF) to measure the blood perfusion signals of fingertips in the vibrated hand and the contralateral middle finger under the same frequency and different amplitude vibration, and to analyze the changes of microcirculatory blood perfusion levels in the fingers, and to investigate the effects of vibration stimulation on the endothelial, neural and myogenic regulatory frequency ranges of fingertips based on wavelet analysis. Furthermore, the transparent silicone films were fabricated and cultured with vascular endothelial cell (EC), which will undergo the local vibration with varied amplitude. And the expression of inflammatory factors was detected in the ECs. Results: Low-frequency vibration leads to a decreased blood flow in fingertip, and the degree of reduction in fingertip blood flow increases as the amplitude gradually increases, and the period required for blood flow to return to normal level after hand-transmitted vibration gradually increases. The decrease in blood flow is more pronounced in the vibrating hand than in the contralateral hand. In addition, nuclear factor-κB (NF-κB) expression increased significantly with the increase of vibration amplitude. Conclusion: High amplitude vibrations caused the inflammatory reaction of ECs which will lead to the altered endothelial regulatory activity. The endothelial regulatory activity is closely related to the blood perfusion in the microcirculation.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

