Related Experiment Video
Updated: Aug 10, 2026

Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
Quality by design paradigm for optimization of green stability indicating HPLC method for concomitant determination
Amira H Kamal1, Ahmed A Habib1, Sherin F Hammad1
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt.
Abstract:
A green, robust and fast stability indicating chromatographic method has been developed for concomitant analysis of fluorescein sodium and benoxinate hydrochloride in the presence of their degradation products within four minutes. Two different designs including fractional factorial and Box-Behnken designs were implemented for screening and optimization steps, respectively. The optimum chromatographic analysis was achieved using a mixture of isopropanol and 20 mM potassium dihydrogen phosphate solution (pH 3.0) in the ratio 27:73 as mobile phase. The flow rate was 1.5 mL/min and column oven temperature was 40 °C. Chromatographic analysis was performed on Eclipse plus C18 (100 mm × 4.6 mm × 3.5 μm) column with DAD detector set at 220 nm. A linear response was acquired over the range of 2.5-60 μg/mL and 1-50 μg/mL for benoxinate and fluorescein respectively. Stress degradation studies were executed under acidic, basic, and oxidative stress conditions. The method was implemented for quantitation of cited drugs in ophthalmic solution with mean percent recovery ± SD of 99.21 ± 0.74 and 99.88 ± 0.58 for benoxinate and fluorescein respectively. The proposed method is more rapid and eco-friendly compared to the reported chromatographic methods for determination of cited drugs.
More Related Videos
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors