Background:
Though vancomycin-soaked graft reduces the infection rate after ACL reconstruction, concerns exist regarding this usage. Gentamicin has been used for graft soakage with satisfactory clinical results but gentamicin's elution characteristics are unknown.
Methods:
Thirty Bovine tendon grafts were harvested from ten limbs under sterile conditions. Three tendons from each of the limbs were allotted into three groups and soaked in either saline, gentamicin or vancomycin. Pre-soakage and post-soakage swabs were cultured. Soaked grafts were immersed in a 10 ml saline solution for 5 min (initial washout) and then in another 10 ml saline solution (sustained release) for 10 min. No 1 Whatman filter paper was immersed in the solutions and placed on culture plates streaked with coagulase-negative Staphylococcus aureus (CONS) and methicillin-resistant Staphylococcus aureus (MRSA), and inhibition was noted. The difference between the two proportions was assessed by two proportion t-test for p < 0.05.
Results:
No organism was cultured in the pre-soakage or post-soakage swab in any specimen. Specimens from one limb were excluded since saline-soakage showed inhibition. Elution from gentamicin-soaked graft inhibited CONS in eight out of nine samples in initial washout and all samples in sustained release solution but inhibited MRSA only in one sample in sustained release solution and the initial washout solution. Vancomycin elution inhibited both organisms in all samples.
Conclusions:
Gentamicin elution from tendon graft achieves minimal inhibitory concentration against susceptible organisms. Though its clinical utility is restricted by limited antimicrobial spectrum, and it could be used where the risk of contamination by MRSA is low.