Predictor factors for non-invasive mechanical ventilation failure in severe COVID-19 patients in the intensive care
Antonio Romanelli1, Pietro Toigo2, Giuliana Scarpati2,3
1Department of Anaesthesia and Intensive Care, AOU "San Giovanni di Dio e Ruggi D'Aragona", Salerno, Italy. antonioromanelli86@gmail.com.
Background:
During the COVID-19 pandemia, non-invasive mechanical ventilation (NIV) has been largely applied. Few data are available about predictors of NIV failure in critical COVID-19 patients admitted to ICU. The aim of this study is to analyze clinical and laboratory features able to predict non-invasive ventilation success in avoiding endotracheal intubation.
Methods:
A retrospective observational study was performed in our COVID-19 ICU during a 6-month period. Demographic, clinical, laboratory, imaging, and outcome data were extracted from electronic and paper medical records and anonymously collected.
Results:
Eighty-two severe COVID-19 patients were supported by NIV at ICU admission. The median PaO2/FiO2 ratio was 125 [98.5-177.7]. NIV failed in 44 cases (53%). Patients who experienced NIV failure had a higher Charlson Comorbidity Index (median value 4) compared to those who were dismissed without endotracheal intubation (median 2, p < 0.0001). At Cox regression analysis, the Charlson Comorbidity Index represented a predictive factor related to NIV failure. PaO2/FiO2, CPK, INR, and AT III at ICU admission showed a significant relationship with the outcome, when single variables were adjusted for the Charlson Comorbidity Index.
Conclusion:
The Charlson Comorbidity Index may be helpful to stratify patients' risk of NIV failure in a severe COVID-19 population; even if this study, retrospective design does not allow definitive conclusions.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...