Related Experiment Video
Updated: Jul 25, 2025

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
4D-printed needle panel meters coupled with enzymatic derivatization for reading urea and glucose concentrations in
Chun-Yi Wu1, Yi-Ting Su1, Cheng-Kuan Su1
1Department of Chemistry, National Chung Hsing University, Taichung City, 402, Taiwan, ROC.
Abstract:
On-site analytical techniques continue being developed with advances in modern technology. To demonstrate the applicability of four-dimensional printing (4DP) technologies in the direct fabrication of stimuli-responsive analytical devices for on-site determination of urea and glucose, we used digital light processing three-dimensional printing (3DP) and 2-carboxyethyl acrylate (CEA)-incorporated photocurable resins to fabricate all-in-one needle panel meters. When adding a sample having a value of pH above the pKa of CEA (ca. 4.6-5.0) into the fabricated needle panel meter, the [H+]-responsive layer of the needle, printed using the CEA-incorporated photocurable resins, swelled as a result of electrostatic repulsion among the dissociated carboxyl groups of the copolymer, leading to [H+]-dependent bending of the needle. When coupled with a derivatization reaction (urease-mediated hydrolysis of urea to decrease [H+]; glucose oxidase-mediated oxidization of glucose to increase [H+]), the bending of the needle allowed reliable quantification of urea or glucose when referencing pre-calibrated concentration scales. After method optimization, the method's detection limits for urea and glucose were 4.9 and 7.0 μM, respectively, within a working concentration range from 0.1 to 10 mM. We verified the reliability of this analytical method by determining the concentrations of urea and glucose in samples of human urine, fetal bovine serum, and rat plasma with spike analyses and comparing the results with those obtained using commercial assay kits. Our results confirm that 4DP technologies can allow the direct fabrication of stimuli-responsive devices for quantitative chemical analysis, and that they can advance the development and applicability of 3DP-enabling analytical methods.
More Related Videos
10:00Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Published on: October 12, 2015
08:15Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications
Published on: November 28, 2017