Related Experiment Video
Updated: Jul 25, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Safely Reducing Unnecessary Radiographs in Suspected Pediatric Musculoskeletal Injuries: A Multidisciplinary
Sarah Lander1, Sarah Obudzinski2, Julie Michels3
1From the Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY.
Background:
While radiographs are a critical component of diagnosing musculoskeletal (MSK) injuries, they are associated with radiation exposure, patient discomfort, and financial costs. Our study initiative was to develop a system to diagnose pediatric MSK injuries efficiently while minimizing unnecessary radiographs.
Methods:
This was a quality improvement trial performed prospectively at a single level one trauma center. A multidisciplinary team with leaders from pediatric orthopedics, trauma surgery, emergency medicine, and radiology created an algorithm delineating which x-rays should be obtained for pediatric patients presenting with MSK injuries. The intervention was performed in the following 3 stages: stage 1: retrospective validation of the algorithm, stage 2: implementation of the algorithm, and stage 3: sustainability evaluation. Outcomes measured included number of extra radiographs per pediatric patient and any missed injuries.
Results:
In stage 1, 295 patients presented to the pediatric emergency department with MSK injuries. A total of 2148 radiographs were obtained, with 801 not indicated per the protocol, for an average of 2.75 unnecessary radiographs per patient. No injuries would have been missed using the protocol. In stage 2, 472 patients had 2393 radiographs with 339 not indicated per protocol, averaging 0.72 unnecessary radiographs per patient, a significant reduction from stage 1 ( P < 0.001). There were no missed injuries identified on follow-up. In stage 3, improvement was sustained for the subsequent 8 months with an average of 0.34 unnecessary radiographs per patient ( P < 0.05).
Conclusions:
Sustained reduction of unnecessary radiation to pediatric patients with suspected MSK injuries was accomplished through the development and implementation of a safe and effective imaging algorithm. The multidisciplinary approach, widespread education of pediatric providers, and standardized order sets improved buy-in and is generalizable to other institutions.Level of Evidence: III.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...