Facilitating structural elucidation of small environmental solutes in RPLC-HRMS by retention index prediction
Ardiana Kajtazi1, Giacomo Russo2, Kristina Wicht1
1Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4bis, B-9000 Ghent, Belgium.
Abstract:
Implementing effective environmental management strategies requires a comprehensive understanding of the chemical composition of environmental pollutants, particularly in complex mixtures. Utilizing innovative analytical techniques, such as high-resolution mass spectrometry and predictive retention index models, can provide valuable insights into the molecular structures of environmental contaminants. Liquid Chromatography-High-Resolution Mass Spectrometry is a powerful tool for the identification of isomeric structures in complex samples. However, there are some limitations that can prevent accurate isomeric structure identification, particularly in cases where the isomers have similar mass and fragmentation patterns. Liquid chromatographic retention, determined by the size, shape, and polarity of the analyte and its interactions with the stationary phase, contains valuable 3D structural information that is vastly underutilized. Therefore, a predictive retention index model is developed which is transferrable to LC-HRMS systems and can assist in the structural elucidation of unknowns. The approach is currently restricted to carbon, hydrogen, and oxygen-based molecules <500 g mol-1. The methodology facilitates the acceptance of accurate structural formulas and the exclusion of erroneous hypothetical structural representations by leveraging retention time estimations, thereby providing a permissible tolerance range for a given elemental composition and experimental retention time. This approach serves as a proof of concept for the development of a Quantitative Structure-Retention Relationship model using a generic gradient LC approach. The use of a widely used reversed-phase (U)HPLC column and a relatively large set of training (101) and test compounds (14) demonstrates the feasibility and potential applicability of this approach for predicting the retention behaviour of compounds in complex mixtures. By providing a standard operating procedure, this approach can be easily replicated and applied to various analytical challenges, further supporting its potential for broader implementation.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
09:09Preparation of Human Tissues Embedded in Optimal Cutting Temperature Compound for Mass Spectrometry Analysis
Published on: April 27, 2021
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Resolution Mass Spectrometry (HRMS)
High-Performance Liquid Chromatography: Types of Detectors
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: