Related Experiment Video
Updated: Jul 24, 2025

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Trends in outcomes associated with the use of Auryon atherectomy system in a real-world setting
1Endovascular Consultants of Colorado, Lone Tree, CO 80124, United States of America.
Background:
While endovascular approaches are considered first line treatment for stenosis or occlusion of the lower limb arteries, major dissections and embolic events remain procedural risks. Newer technologies are needed which limit these complications while achieving desired clinical outcomes.
Methods:
The Auryon atherectomy system (AngioDynamics) consists of a 355-nm wavelength solid-state Nd:YAG short pulse laser combined with dedicated optical catheters. This single-center, retrospective chart review assessed the safety and efficacy of this device in patients with PAD treated at our center between March and December 2020.
Results:
A total of 55 patients were included. Mean age was 73.7 ± 9.3 years with 63.6 % of patients being males. Lesions were above the knee only for 16.4 % of patients, below the knee only for 3.6 %, and both above and below the knee for 80.0 % of patients. One patient had in-stent restenosis. Chronic total occlusions and critical limb ischemia were present for 43.6 % of patients respectively. Procedural success, defined as <30 % residual stenosis without any complications, was achieved in 85.5 % of patients. Stenosis/re-occlusion occurred in 25.5 % of patients at a mean of 168.9 ± 73.4 days with resultant target lesion revascularization (TLR) at 218.3 ± 92.4 days. Four patients underwent minor amputations. No patients experienced procedure-related complications. One patient died unrelated to the procedure.
Conclusion:
The Auryon laser system was shown to be safe and effective in this real-world patient population with no procedural adverse events or deaths and improvements in patient outcomes.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
23:33The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Related Concept Videos
Atherosclerosis III: Management
Atherosclerosis IV: Nursing Management
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Peripheral Artery Disease III: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies
Atherosclerosis I: Introduction