Related Experiment Video
Updated: Jul 24, 2025

07:03
Dynamic Navigation in Endodontics: Guided Access Cavity Preparation by Means of a Miniaturized Navigation System
Published on: May 5, 2022
4.5K
Comparative Evaluation of a Dynamic Navigation System versus a Three-dimensional Microscope in Retrieving Separated
Mohammed H Karim1, Bestoon M Faraj1
1Conservative Department, University of Sulaimani, College of Dentistry, Iraq.
Journal of Endodontics
|July 2, 2023
Summary
Microscope guidance is superior to dynamic navigation for retrieving broken Nickel-Titanium files, offering better outcomes in terms of time, errors, and root canal volume changes.
Area of Science:
- Endodontics
- Dental Materials Science
Background:
- Separated rotary Nickel-Titanium files pose a significant challenge in endodontic retreatment.
- Effective retrieval methods are crucial to avoid procedural complications and preserve root canal anatomy.
Purpose of the Study:
- To compare the effectiveness of dynamic navigation systems versus three-dimensional microscopes for retrieving fractured Nickel-Titanium rotary files.
- To evaluate success rate, canal aberration, treatment time, and volumetric changes associated with each guidance system.
Main Methods:
- Sixty fractured Nickel-Titanium rotary files were retrieved from 30 maxillary first bicuspids using trepan burs and an extractor system.
- Teeth were divided into two groups: dynamic navigation system guidance and three-dimensional microscope guidance.
- Key outcome measures included retrieval success, canal aberration, time, and root canal volumetric changes.
Main Results:
- The three-dimensional microscope group demonstrated a trend towards a higher success rate, though not statistically significant.
- Microscope guidance resulted in significantly lower canal aberration, reduced treatment time, and minimal root canal volume changes compared to dynamic navigation.
- No significant difference was found in the success rate between the two guidance systems (P > 0.05).
Conclusions:
- While dynamic navigation can retrieve separated instruments, it is less effective than three-dimensional microscope guidance.
- Three-dimensional microscope guidance offers superior outcomes in managing procedural errors and preserving root canal morphology during file retrieval.