Related Experiment Video
Updated: Jul 24, 2025

Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024
Flexural strength and microhardness of human radicular dentin sticks after conditioning with different endodontic
Ahmed El-Banna1, Maii Y Elmesellawy2, Mohamed Ahmed Elsayed3,4
1Department of Biomaterials, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Introduction:
The objective of this in vitro study was to examine the impact of different endodontic chelating agents on the flexural strength and microhardness of root dentin.
Materials And Methods:
Fourty dentin sticks of (1 mm × 1 mm × 12 mm) were obtained from 10 single-rooted premolars and divided into four groups (n = 10). One stick from each tooth was assigned to one of the experimental groups and was soaked in one of the experimental chelating solutions for 5 min 17% ethylenediaminetetraacetic acid (EDTA), 2.5% phytic acid (PA), 18% etidronic acid, or saline (control group). Following the 5-min soak, the sticks' flexural strength was evaluated using a 3-point loading test using the universal testing machine, and the surface microhardness was tested using a Vickers's microhardness tester.
Results:
PA (2.5%) and etidronic acid (18%) showed no significant detrimental effect on either the flexural strength or the surface microhardness of radicular dentin compared to the control. EDTA (17%) exhibited a significant drop in the flexural strength and microhardness of radicular dentin compared to the other groups.
Conclusions:
PA and etidronic acid chelators do not compromise the surface and bulk mechanical properties of radicular dentin.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Chemistry and Properties
Complexometric Titration: Ligands