Related Experiment Video
Updated: Jul 24, 2025

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Exposure to hand-held vibrating tools and biomarkers of nerve injury in plasma: a population-based, observational
Malin Zimmerman1,2, Peter Nilsson3, Lars B Dahlin4,5
1Department of Translational Medicine, Lund University, Malmö, Sweden.
Objectives:
To analyse potential biomarkers for vibration-induced nerve damage in a population-based, observational study.
Design:
Prospective cohort study.
Setting:
Malmö Diet Cancer Study (MDCS), Malmö, Sweden.
Participants:
In a subcohort of 3898 individuals (recruited 1991-1996) from MDCS (baseline examination in 28 449 individuals; collection of fasting blood samples in a cardiovascular subcohort of MDCS of 5540 subjects), neuropathy-relevant plasma biomarkers were analysed during follow-up after filling out questionnaires, including a question whether work involved hand-held vibrating tools, graded as 'not at all', 'some' or 'much'.
Primary Outcome Measures:
The neuropathy-relevant plasma biomarkers vascular endothelial growth factor (VEGF)-A, VEGF-D, VEGF receptor 2, galanin, galectin-3, HSP27, ß-nerve growth factor, caspase-3, caspase-8, transforming growth factor-α and tumour necrosis factor were analysed. Data were analysed by conventional statistics (Kruskal-Wallis test; post hoc test Mann-Whitney U test; Bonferroni correction for multiple testing) and in a subanalysis for galanin using two linear regression models (unadjusted and adjusted).
Results:
Among participants, 3361 of 3898 (86%) reported no work with hand-held vibrating tools, 351 of 3898 (9%) reported some and 186 of 3898 (5%) much work. There were more men and smokers in vibration-exposed groups. Galanin levels were higher after much vibration exposure (arbitrary units 5.16±0.71) compared with no vibration exposure (5.01±0.76; p=0.015) with no other observed differences.
Conclusions:
Higher plasma levels of galanin, possibly related to magnitude, frequency, acceleration and duration, as well as to severity of symptoms of vibration exposure, may be found in individuals working with hand-held vibrating tools.