Related Experiment Video
Updated: Jul 24, 2025

Anatomically Realistic Neonatal Heart Model for Use in Neonatal Patient Simulators
Published on: February 5, 2019
Amplification of Heart Sounds Using Digital Stethoscope in Simulation-Based Neonatal Resuscitation
Anirudha Das1, Kim Adams1, Shelagh Stoicoiu1
1Department of Neonatology, Cleveland Clinic Children's Hospital, Cleveland, Ohio.
Objective:
The accuracy, timeliness, and reliability of the current methods of heart rate (HR) determination in neonatal resuscitation are debatable, each having its own limitations. We aim to compare three methods of HR assessment: (1) traditional stethoscope, (2) electrocardiogram and traditional stethoscope, and (3) digital stethoscope with loudspeaker amplification of heart sounds.
Study Design:
This was a simulated crossover experiment using a high-fidelity manikin. Each team with a physician, a nurse, and a respiratory therapist performed the resuscitations using the three methods (three different scenarios) in different order. The person controlling the HR via manikin controller was blinded, but the single recorder and the providers were not.
Results:
Eighteen resuscitations were completed (six teams of three methods each). The time to first HR recording (p < 0.001), total number of HR recorded (p < 0.001), and time to recognize dips in HR was significantly improved in the digital stethoscope group (p = 0.009).
Conclusion:
Use of digital stethoscope with amplification improved documentation of HR and earlier recognition of HR changes.
Key Points:
· Amplified heartbeats during neonatal resuscitation improved documentation.. · Amplified infant heartbeats resulted in earlier recognition of HR changes (increase or decrease).. · Providers using this method had greater satisfaction..
More Related Videos
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: