Fully convolutional neural network and PPG signal for arterial blood pressure waveform estimation
Yongan Zhou1, Zhi Tan1, Yuhong Liu2,3
1School of Electrical and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, 100044, People's Republic of China.
Abstract:
Objective. The quality of the arterial blood pressure (ABP) waveform is crucial for predicting the value of blood pressure. The ABP waveform is predicted through experiments, and then Systolic blood pressure (SBP), Diastolic blood pressure, (DBP), and Mean arterial pressure (MAP) information are estimated from the ABP waveform.Approach. To ensure the quality of the predicted ABP waveform, this paper carefully designs the network structure, input signal, loss function, and structural parameters. A fully convolutional neural network (CNN) MultiResUNet3+ is used as the core architecture of ABP-MultiNet3+. In addition to performing Kalman filtering on the original photoplethysmogram (PPG) signal, its first-order derivative and second-order derivative signals are used as ABP-MultiNet3+ enter. The model's loss function uses a combination of mean absolute error (MAE) and means square error (MSE) loss to ensure that the predicted ABP waveform matches the reference waveform.Main results. The proposed ABP-MultiNet3+ model was tested on the public MIMIC II databases, MAE of MAP, DBP, and SBP was 1.88 mmHg, 3.11 mmHg, and 4.45 mmHg, respectively, indicating a small model error. It experiment fully meets the standards of the AAMI standard and obtains level A in the DBP and MAP prediction standard test under the BHS standard. For SBP prediction, it obtains level B in the BHS standard test. Although it does not reach level A, it has a certain improvement compared with the existing methods.Significance. The results show that this algorithm can achieve sleeveless blood pressure estimation, which may enable mobile medical devices to continuously monitor blood pressure and greatly reduce the harm caused by Cardiovascular disease (CVD).
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: