Geographical balancing of wind power decreases storage needs in a 100% renewable European power sector

Alexander Roth1, Wolf-Peter Schill1

  • 1German Institute for Economic Research (DIW Berlin), Mohrenstraße 58, 10117 Berlin, Germany.

Iscience
|July 6, 2023
PubMed

Related Concept Videos

Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
290
Generation of Three-Phase Voltage01:21

Generation of Three-Phase Voltage

A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
419
Energy Stored in Capacitors01:10

Energy Stored in Capacitors

A parallel plate capacitor, when connected to a battery, develops a potential difference across its plates. This potential difference is key to the operation of the capacitor, as it determines how much electrical energy the capacitor can store.
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
543
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
292
Energy Stored in a Capacitor01:12

Energy Stored in a Capacitor

When an archer pulls the string in a bow, he saves the work done in the form of elastic potential energy. When he releases the string, the potential energy is released as kinetic energy of the arrow. A capacitor works on the same principle in which the work done is saved as electric potential energy. The potential energy (UC) could be calculated by measuring the work done (W) to charge the capacitor.
3.7K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138