Related Experiment Video
Updated: Jul 24, 2025

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
Estimated glomerular filtration rate from the renal hypothermia trial: clinical implications
Francis Lemire1, Dean A Fergusson2, Greg Knoll3,2
1Division of Urology, Department of Surgery, The Ottawa Hospital, Ottawa, ON, Canada.
Objective:
To assess if estimated glomerular filtration rate (eGFR) can replace measured GFR (mGFR) in partial nephrectomy (PN) trials, using data from a randomised clinical trial.
Patients And Methods:
We conducted a post hoc analysis of the renal hypothermia trial. Patients underwent mGFR with diethylenetriaminepentaacetic acid (DTPA) plasma clearance preoperatively and 1 year after PN. The eGFR was calculated using the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) creatinine equations incorporating age and sex, with and without race: 2009 eGFRcr(ASR) and 2009 eGFRcr(AS), and the 2021 equation that only incorporates age and sex: 2021 eGFRcr(AS). Performance was evaluated by determining the median bias, precision (interquartile range [IQR] of median bias), and accuracy (percentage of eGFR within 30% of mGFR).
Results:
Overall, 183 patients were included. Pre- and postoperative median bias and precision were similar between the 2009 eGFRcr(ASR) (-0.2 mL/min/1.73 m2 , 95% confidence interval [CI] -2.2 to 1.7, IQR 18.8; and -2.9, 95% CI -5.1 to -1.5, IQR 15, respectively) and 2009 eGFRcr(AS) (-0.3 mL/min/1.73 m2 , 95% CI -2.4 to 1.5, IQR 18.8; and -3.0, 95% CI -5.7 to -1.7, IQR 15.0, respectively). Bias and precision were worse for the 2021 eGFRcr(AS) (-8.8 mL/min/1.73 m2 , 95% CI -10.9 to -6.3, IQR 24.7; and -12.0, 95% CI -15.8 to -8.9, IQR 23.5, respectively). Similarly, pre- and postoperative accuracy was >90% for the 2009 eGFRcr(ASR) and 2009 eGFRcr(AS) equations. Accuracy was 78.6% preoperatively and 66.5% postoperatively for 2021 eGFRcr(AS).
Conclusion:
The 2009 eGFRcr(AS) can accurately estimate GFR in PN trials and could be used instead of mGFR to reduce cost and patient burden.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Acute Kidney Injury I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Acute Kidney Injury III: Clinical Manifestations
Acute Kidney Injury V: Interprofessional Care