Effect of 3-Dimensional Imaging Device on Polyp and Adenoma Detection During Colonoscopy: A Randomized Controlled
Xiujing Sun1, Qian Zhang1, Shanshan Wu1
1Department of Gastroenterology, Beijing Friendship Hospital, Capital Medical University, National Clinical Research Center for Digestive Disease, Beijing Digestive Disease Center, Beijing Key Laboratory for Precancerous Lesion of Digestive Disease, Beijing, China.
Introduction:
To evaluate the effect of 3-dimensional (3D) imaging device on polyp and adenoma detection during colonoscopy.
Methods:
In a single-blind, randomized controlled trial, participants aged 18-70 years who underwent diagnostic or screening colonoscopy were consecutively enrolled between August 2019 and May 2022. Each participant was randomized in a 1:1 ratio to undergo either 2-dimensional (2D-3D) colonoscopy or 3D-2D colonoscopy through computer-generated random numbers. Primary outcome included polyp detection rate (PDR) and adenoma detection rate (ADR), defined as the proportion of individuals with at least 1 polyp or adenoma detected during colonoscopy. The primary analysis was intention-to-treat.
Results:
Of 1,196 participants recruited, 571 in 2D-3D group and 583 in 3D-2D group were finally included after excluding those who met the exclusion criteria. The PDR between 2D and 3D groups was separately 39.6% and 40.5% during phase 1 (odds ratio [OR] = 0.96, 95% confidence interval [CI]: 0.76-1.22, P = 0.801), whereas PDR was significantly higher in 3D group (27.7%) than that of 2D group (19.9%) during phase 2, with a 1.54-fold increase (1.17-2.02, P = 0.002). Similarly, the ADR during phase 1 between 2D (24.7%) and 3D (23.8%) groups was not significant (OR = 1.05, 0.80-1.37, P = 0.788), while ADR was significantly higher in 3D group (13.8%) than that of 2D group (9.9%) during phase 2, with a 1.45-fold increase (1.01-2.08, P = 0.041). Further subgroup analysis confirmed significantly higher PDR and ADR of 3D group during phase 2, particularly in midlevel and junior endoscopists.
Discussion:
The 3D imaging device could improve overall PDR and ADR during colonoscopy, particularly in midlevel and junior endoscopists. Trial number: ChiCTR1900025000.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Three-Dimensional Microscopy in Microbiology