Accuracy of Pulse Oximetry for Long-Term Oxygen Therapy Assessment in Chronic Obstructive Pulmonary Disease
Brian Garnet1,2, Rodrigo Diaz-Lankenau3, Elie Jean3
1Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, University of Miami, Miami, Florida; and.
Abstract:
Rationale: Landmark studies of long-term oxygen therapy (LTOT) in patients with chronic obstructive pulmonary disease (COPD) used arterial oxygen pressure (PaO) to define severe hypoxemia; however, oxygen saturation as measured by pulse oximetry (SpO) is commonly used instead. The Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines recommend evaluation with arterial blood gas (ABG) analysis if SpO is ⩽92%. This recommendation has not been evaluated in stable outpatients with COPD undergoing testing for LTOT. Objectives: To evaluate the performance of SpO compared with ABG analysis of PaO and arterial oxygen saturation (SaO) to detect severe resting hypoxemia in patients with COPD. Methods: Retrospective analysis of paired SpO and ABG values from stable outpatients with COPD who underwent LTOT assessment in a single center. We calculated false negatives (FNs) as an SpO >88% or >89% in the presence of pulmonary hypertension with a PaO ⩽55 mm Hg or ⩽59 mm Hg in the presence of pulmonary hypertension. Test performance was assessed using receiver operating characteristic (ROC) analysis, intraclass correlation coefficient (ICC), test bias, precision, and accuracy root-mean-square (Arms). An adjusted multivariate analysis was used to evaluate factors affecting SpO bias. Results: Of 518 patients, the prevalence of severe resting hypoxemia was 74 (14.3%), with 52 missed by SpO (FN, 10%), including 13 (2.5%) with an SpO > 92% (occult hypoxemia). FNs and occult hypoxemia in Black patients were 9% and 1.5%, respectively, and were 13% and 5%, respectively, among active smokers. The correlation between SpO and SaO was acceptable (ICC = 0.78; 95% confidence interval, 0.74-0.81); and the bias of SpO was 0.45%, with a precision of 2.6 (-4.65 to +5.55%) and Arms of 2.59. These measurements were similar in Black patients, but in active smokers, correlation was lower and bias showed greater overestimation of SpO. ROC analysis suggests that the optimal SpO cutoff to warrant LTOT evaluation by ABG analysis is ⩽94%. Conclusions: SpO as the only measure of oxygenation carries a high FN rate in detecting severe resting hypoxemia in patients with COPD undergoing evaluation for LTOT. Reflex measurement of PaO by ABG analysis should be used as recommended by GOLD, ideally at a cutoff higher than an SpO ⩽92%, especially in active smokers.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...