Related Experiment Video
Updated: Jul 24, 2025

Synthesis and Characterization of 1,2-Dithiolane Modified Self-Assembling Peptides
Published on: August 20, 2018
Safety data sheets as an information pathway on hazards of occupationally used cleaning agents
Behnaz Erfani1, Libe Vilela1, Anneli Julander2
1Institute of Environmental Medicine, Karolinska Institutet, Sweden.
Abstract:
To investigate consistency and accessibility of asthma and skin allergy hazard information in safety data sheets (SDSs) for cleaning agents on the Swedish market, we compiled a database of 504 SDSs and 351 therein declared ingredients. Labelling of products was compared to that of ingredients according to harmonised classification. For each ingredient, also notified classification and three additional sources on sensitising properties were compared. Product labelling most frequently indicated corrosion and irritation hazards. Only 3% of products were labelled as skin sensitisers and none as asthmagens. According to harmonised classification, 9% of products contained skin sensitisers, using other information sources increased the number to 46%. While 2% of products contained respiratory sensitisers according to harmonised classification, the number increased to 17% when using other information sources. Furthermore, sensitisers were declared across several sections of the SDSs, hampering easy access of such information. In conclusion, there are inconsistencies in hazard identification of cleaning agents and their ingredients. Hence, SDSs may not altogether fulfil its hazard information role. Improved criteria for identifying sensitisers and respiratory irritants are warranted. Additionally, we argue that all ingredients should be listed in section 3 regardless of concentration, to facilitate access of information about sensitising properties.
More Related Videos
09:54Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 1. Biosafety Level 4 Suit Laboratory Suite Entry and Exit Procedures
Published on: October 3, 2016
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Personal Protective Equipment
PPE Use in Healthcare Settings II: Doffing
Chemical Agents for Microbial Control
PPE Use in Healthcare Settings I: Donning
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...